ACCEPTANCE CRITERIA OF WELD DEFECTS AS PER DIFFERENT CODE ( ASTM B 31.1 / AWS D1.1)


ACCEPTANCE CRITERIA OF WELD DEFECTS AS PER DIFFERENT CODES:

ASTM B 31.1 BOILER PIPING CODE

VISUAL EXAMINATION – Acceptance criteria
Cracks on external surface
Undercuts on external surface > 1 mm deep
Weld reinforcement more than specified
Lack of fusion on surface
Incomplete penetration in root if accessible

ASTM B 31.1 BOILER PIPING CODE

MAGNETIC PARTICLE EXAMINATION

Relevant indication is one from unacceptable
mechanical discontinuities. Size of indication is the
criteria and not the size of defect.
Acceptance criteria
Cracks or linear indication ( L > 3 W)
Rounded indications dimension > 4.8 mm
Four or more rounded indications in a line
separated by 1.6 mm edge to edge
Ten or more rounded indications in any 6 sq. in.
surface with major dimension < 6 in

ASTM B 31.1 and ASME VIII

RADIOGRAPHIC EXAMINATION –
Acceptance criteria
Cracks or incomplete fusion
Elongated indications
6.4 mm for thickness up to 19 mm
1/3 t for thickness from 19 - 56 mm
19 mm for thickness more than 56 mm
Group of aligned indications with aggregate
length more than t in a length of 12 t
Rounded indications as per chart


ASME VIII BOILER & PR VESSEL CODE

ROUNDED INDICATIONS –
A sequence of 4 or more rounded indications are
aligned when they touch a line parallel to length of
line drawn through center of outer indications
thickness
Relevant indication
1/8 “ t / 10
1/8 to 1/4”. 1/64”
1/4 to 2” 1/32”
> 2” 1/16”

ASME B 31.3 PROCESS PIPING CODE -

NON DESTRUCTIVE EXAMINATION REQUIRED

• Visual examination of randomly selected
materials
• Visual examination of 5% min of fabrication
• 100% visual examination of longitudinal welds
• Random visual examination during erection of
piping for defects which require repair
• Minimum 5% of circumferential butt welds shall
be examined by random RT. For cyclic loaded pipe,
100% RT needed
• When circ. joint intersects with long. joint at
least 38 mm of each intersecting weld shall be

Acceptance Criteria as per ASME B 31.3

Normal fluid service
(a) Crack, Lack of fusion (VT &RT) No evident imperfection
(b) Incomplete penetration (VT & RT) in Long grooves no
evident imperfection. In girth welds and branch conn., depth
permitted is 1 mm and 0.2 t. Cumulative <38 mm in any
150 mm weld length
(c) Internal porosity (RT) in girth, long, branch con., as per
ASME VIII
(d) Slag / W inclusion (RT) in girth, long and branch welds -
individual length < 2t, individual width < 3 mm & 0.5 t,
cumulative length <4t in any 150 mm weld length
(e) Undercut(VT) in girth, fillet and branch welds - depth < 1
mm & 0.25 t. For long welds no evident undercut


Acceptance Criteria as per ASME B 31.3

Normal fluid service
(f) Surface porosity (VT) No evident imperfection
(g) Concave root surface in butt welds (VT & RT) - Total
joint thickness incl weld reinf > t
(h) Reinforcement or internal protrusion (VT)
t Max height
<=6 1.5
6 to 13 3
13 to 25 4
>25 5

Acceptance Criteria as per ASME B 31.3
Severe cyclic condition
(a) Crack (VT,RT,MT,PT), Lack of fusion (VT,RT) - No evident
imperfection
(b) Incomplete penetration (VT & RT) in girth, long and
branch welds no evident imperfection.
(c) Internal porosity (RT) in girth, long, branch con., as per
ASME VIII
(d) Slag / W inclusion (RT) in girth, long and branch welds -
individual length < t/3, individual width < 2.5 mm & t/3,
cumulative length < t in any 12 t weld length

Acceptance Criteria as per ASME B 31.3

Category D fluid service
(a) Crack (VT) - No evident imperfection
(b) Lack of fusion (VT) in long & branch weld - No evident
imperfection. In girth weld, depth < 0.2 t cumulative length
< 38 mm in any 150 mm length
(c) Incomplete penetration (VT ) in girth weld same as lack
of fusion. In long weld no evident imperfection. In branch
welds depth < 1 mm & 0.2 t. Cumulative length < 38 mm in
any 150 mm length
(d) Undercut (VT) in girth weld < 1.5 mm & < t/4. In long
weld no evident imperfection. In fillet and branch weld < 1
mm & t/4
(e) Surface porosity (VT) no evident imperfection

Acceptance Criteria as per ASME B 31.3
Category D fluid service
(f) Concave root surface in butt welds (VT) - Total joint
thickness incl weld reinf > t
(g) Reinforcement or internal protrusion (VT)
t Max height
<=6 3.0
6 to 13 6
13 to 25 8
>25 10

AWS D 1.1 STRUCTURAL WELDING CODE

Static load, Cyclic load & Tubular connections
(a) Crack
Weld shall have no crack
(b) Weld / Base Thorough fusion shall exist bet’ WM/BM
metal fusion and adjacent layers of WM
(c ) Crater
Crater to be filled to full cross section
except for stitch welds outside eff. Len.
(d) Weld profile In conformance with sketch
(e) Inspection VT to start after weld cools to room temp
(f) UnderrunUnderrun in fillet weld nominal size 1.6
mm provided it is < 10% length. In Web to
flange welds,

AWS D 1.1 STRUCTURAL WELDING CODE

(g) Undercut In static loading, 1 mm permitted for t<25
and 1.6 mm in t>25mm. For t<25 mm, Max
1.6 mm
permitted for accumulated l of 50
mm in 305 mm.
In cyclic loads and tubular connections,
undercut
< 0.25 mm deep when weld is
transverse to tensile
stress. For other cases,
1 mm is permitted
(h) Porosity In complete joint penetration butt joints
transverse to tensile stress, no visible piping
porosity
permitted in static, cyclic & tubular
connection


AWS D 1.1 STRUCTURAL WELDING CODE

Porosity In static loading, for other grooves and
fillets
sum of porosity with dia > 1mm,
should be < 10 mm in
any linear inch of
weld and < 19 mm in any 305 mm
weld
For cyclic loading and tubular connection,
the
frequency of piping porosity in other
cases should be <
one in 100 mm weld
length and max dia < 2 mm.
In cyclic loading and tubular connections,
for
fillet welds connecting stiffeners to web,
the sum of dia
of piping porosity<10 mm in
any linear inch of weld
and shall be < 19
mm in any 305 mm weld

AWS D 1.1 STRUCTURAL WELDING CODE
RADIOGRAPHY FOR STATICALLY LOADED STRUCTURE
Elongated indication and spacing as per chart
Rounded indications > E/3 not to exceed 6 mm (except
for t>2” it is 10 mm) and gap should be > 3 L
Isolated discontinuities like clusters with sum of
dimensions not to exceed chart and gap < 3 L
Sum of individual discontinuities each having max
dimension < 2 mm, shall not exceed 2 E /3 (10 mm max) in
any linear inch of weld.
In line discontinuities with sum of greatest dimension <
E in any 6E length of weld


Comments